Radiography andFluroscopy for dental and mammography dosimeter
Radiography andFluroscopy for dental and mammography dosimeter
X-Ray Multi-Meter Series for Service and QA in R&F, Dental and Mammography
- QUART didoEASY MR Art. 11117 Basic Configuration
- QUART didoEASY+ MR Art. 11117+ Added kV Measurement
- QUART didoEASY++ MR Art. 11117++ Added kV and Direct-HVL Measurement
The QUART didoEASY meters seem tailored for users who prioritize precision in dosimetric applications but may not require the full range of features offered by other dosemeter packages.
High Precision in Basic Configuration: Even in its basic configuration, QUART didoEASY meters offer high precision in measuring essential parameters for service and quality assurance in x-ray equipment. This likely includes measurements such as dose, dose rate, and time, ensuring accuracy in critical operations.
Optional Upgrades: Users have the flexibility to choose from different versions based on their specific needs. The didoEASY+ MR version introduces kVp and PPV measurement capabilities, enhancing the meter's versatility for more comprehensive evaluations.
Advanced Features: For users requiring even more advanced functionalities, the didoEASY++ MR version goes a step further by adding direct-HVL measurement along with kVp and PPV measurement. This version provides a more comprehensive suite of measurements for in-depth analysis and quality assurance.
Specifications
didoEASY MR basic configuration
Dose Measurement:Range: 0.99 µGy to 999 mGy,Uncertainty: ±5% @ 25-40 kV (M), 50-150 kV (R),Resolution: 0.01 µGy
DLP (Dose Length Product) Measurement*:Range: 0.99 µGycm to 999 mGycm,Uncertainty: ±5% @ 50-120 kV,Resolution: 0.01 µGycm
Dose Rate Measurement:Range: 0.5 µGy/s to 999 mGy/s,Uncertainty: ±5% @ 50-150 kV
Resolution: 0.1 µGy/s
Time Measurement:Range: 1.0 ms to 296 s,Uncertainty: ±1.4 ms,Resolution: 0.1 ms
didoEASY+ MR - features added kV measurement
Dose Measurement:Range: 0.99 µGy to 999 mGy,Uncertainty: ±5% @ 25-40 kV (M), 50-150 kV (R),Resolution: 0.01 µGy
DLP (Dose Length Product) Measurement*:Range: 0.99 µGycm to 999 mGycm,Uncertainty: ±5% @ 50-120 kV,Resolution: 0.01 µGycm
Dose Rate Measurement:Range: 0.5 µGy/s to 999 mGy/s,Uncertainty: ±5% @ 50-150 kV,Resolution: 0.1 µGy/s
Time Measurement:Range: 1.0 ms to 296 s,Uncertainty: ±1.4 ms,Resolution: 0.1 ms
Pulses:Range: 1 to 9999,Uncertainty: ±1 pulse
Pulse Rate:Range: 0.1 to 250 pulses/s,Uncertainty: ±0.1 pulses/s
kVp / PPV Measurement:kVp Range (M detectors): 25 to 35 kV,kVp Range (R detectors): 50 to 130 kV,Uncertainty: ±5% at calibrated reference points Resolution: 0.1 kV,Exposure conditions:
Mammography: Mo/Mo; HVL 0.2 – 0.45 mm Al eq., with correction factors provided for further radiation qualities,R&F: HVL 1.5 – 10.5 mm Al eq
didoEASY++ MR - features added kV and direct-HVL measurement
Dose Measurement:Range: 0.99 µGy to 999 mGy,Uncertainty: ±5% @ 25-40 kV (M), 50-150 kV (R),Resolution: 0.01 µGy,DLP
(Dose Length Product) Measurement*:Range: 0.99 µGycm to 999 mGycm, Uncertainty: ±5% @ 50-120 kV,Resolution: 0.01 µGycm
Dose Rate Measurement:Range: 0.5 µGy/s to 999 mGy/s,Uncertainty: ±5% @ 50-150 kV,Resolution: 0.1 µGy/s
Time Measurement:Range: 1.0 ms to 296 s,Uncertainty: ±1.4 ms,Resolution: 0.1 ms